Vaillant ecoTec plus 831 - F.75 error message - faulty expansion vessel (181051)

Vaillant ecotec Plus 831 shows an error code F.75 after few minutes of trying to ignite

  • Check the pressure sensor and the pump. If they both are fine then look at the expansion vessel
  • Open a recharge nipple and press. If water is coming from the vessel then the expansion vessel is faulty and needs replacement.
  • The part numbers are: Vaillant Ecotec Expansion Vessel 181051 

2017-05-06

Boilers

Vaillant Turbomax Plus 837E F.28 Gas valve 114189 Original Sigma 845

Vaillant Turbomax Plus 837E displays an error code F.28

  • If PCB is fine and the spark electrodes are fine the adjust the gas valve ignition burner pressure and operating burner pressure according to the manufacturer's instructions
  • If the pressure adjustments don't last and change by themselves then replace a gas valve
  • Gas valve replacement part is 114189 Original Sigma 845

2017-05-06

Boilers

Glowworm Betacom c24 - Faulty Diverter valve - 0020064049

Glowworm Betacom c24 radiators are getting hot when hot water is running and the hot water is lukewarm

  • Remove a diverter vale motor and try to push a spindle on the divert valve
  • If spindle doesn't come back or doesn't push then replace the diverter valve
  • The replacement part number is 0020064049 
  • While replacing the diverter valve check the secondary (hot water) heat exchanger for sludge. Clean if necessary to fix the problem with lukewarm hot water.
  • Sludge in the system is the main reason for a Diverter valve to fail
  • The whole system powerflush will be advisory.

2017-05-06

Boilers

Ideal Isar HE24 - Faulty Diverter valve (173624)

Ideal Isar HE24 boiler heating radiators when hot water is on.

  • If central heating is OFF but the radiators are still getting hot when hot water is running and hot water temperature is not very hot then the Diverter valve could be a problem
  • To test when the radiators are cold and boiler was not working for a while open hot water tap and touch the right hand-side 22mm pipe.
  • If the pipe is getting hot then replace the diverter valve.
  • Diverter valve kit part number is 173624 

 

2017-04-14

Boilers

Vaillant EcoTec plus 637 F.32 Faulty fan 193593

Vaillant ecoTec plus 637 system boiler doesn't work with a fault code F.32

  • The boiler fan is faulty fan 193593 or a Printed Circuit Board (PCB) is faulty
  • To test take the electrical connection out of the fan and measure DC voltage across Red and Blue wires. The voltage should be 22VDC
  • If no voltage present replace the PCB
  • If voltage is present then replace the fan

2017-04-09