Switch to mobile site
Loading

Maintenance and Service

Exam revision materials for Plumbing Level 2&3 and ACS Gas Safety test

Create an Article

Showers

Triton

Click to show/hide index

Boilers

Alfa Laval

Alpha

Ariston

Baxi

Biasi

Chaffoteaux

Electroheat PLC

Ethos

Ferroli

Glowworm

Halstead

Heat Lline

Ideal

Keston

Main

Myson

Potterton

Saunier Duval

Vaillant

Viessmann Vitodens 100 W Compact

Vokera

Worcester

Showers

Aqualisa

Bristan

Crosswater

Crosswater

Grohe

HUB-001A-WAX Vado Thermostatic Cartridge

Hansgrohe

Hudson Reed

IB

Mira

Porcelanosa

S960134NU Thermostatic Cartridge

Sirrus Rothwell R995 Antique Shower

Trevi

Triton

Triton

Ultra

Vola

Taps

Armitage Shanks

Grohe

Hansgrohe

Mayfair

Phoenix

Space Heaters

Baxi

Remeha

Bathstore Thermostatic Cartridge

Servicing Guide

Pumps

Grundfos

Thermal Store Cylinders

Pulsacoil

Underfloor Heating

PolyPlumb

Toilets

Geberit

Grohe

Hot Water Cylinders

Dimplex

Megaflow

Santon

Gas Safety Inspection

Gas Flue Analysers

Gas Hobs

AGA

Neff

Triton 83310120 Thermostatic Cartridge Problem - No Hot Water or No Cold Water

If only hot water or cold water is coming out of your shower, there are several reasons this could be.  To determine the problem, follow the following steps:

1.  Make sure there is hot water entering the shower.

2.  If there is, the problem could be a pressure issue whereby some shower valves struggle to mix when there is too much pressure from either the hot or the cold feeds.  If your shower was previously working then this shouldn't be a problem as it's likely your pressure will be the same as before.

3.  Now, turn off or isolate the water to the shower.

4.  Remove the 82210120 thermostatic cartridge.  This will remove by pulling it out (not a screw fit).

5.  Make sure there is nothing blocking the cartridge inlets.

6.  If nothing is blocking then it's probably an issue with the inner workings of the cartridge and the cartridge will need to be replaced.

7.  The part needed is the Triton 883310120 thermostatic cartridge.  

8.  This cartridge is also used on Triton Norina, Dart 2, Amala, Altessa, Cassini and Sentiment shower valves.

< Go Back2015-09-18

Triton Triton dart 2 concentric shower valve - thermostatic cartridge replacement 83310120

Triton dart 2 concentric shower valve turn on and off handle is very stiff to open or close

  • Thermostatic cartridge needs to be replaced
  • Waters supply must be isolated before replacing the part
  • The part number is 83310120
< Go Back2014-09-21

Triton Unichrome Tees temperature control is too stiff

Triton Unichrome Tees Square Bar - can't regulate the water temperature. The water temperature regulator is too stiff to turn.

< Go Back2013-10-21